TAKTL / Material dossier 01
A|UHPC® Facade Elements
TAKTL's core architectural concrete panel system for exterior envelopes and selected interior spaces. Project layouts, texture, color and attachment are coordinated with the manufacturer.
Request project pricing
At a glance / Manufacturer facts
- Standard thickness
- 5/8 in (about 16 mm)
- Nominal formats
- 48 × 120 in and 48 × 144 in
- Standard and custom limits
- Format varies by construction; confirm current standard and custom limits with TAKTL
01 / Material profile
The material,
in detail.
TAKTL architectural ultra-high performance concrete; finish and geometry depend on the selected family.
Manufacturer facts
- Standard thickness
- 5/8 in (about 16 mm)
- Nominal formats
- 48 × 120 in and 48 × 144 in
- Standard and custom limits
- Format varies by construction; confirm current standard and custom limits with TAKTL
- Attachment
- Visible fasteners or concealed undercut anchors, subject to assembly design
Values summarize TAKTL literature. Confirm the current revision, assembly and project requirements with the manufacturer.
View the manufacturer source02 / Architectural possibilities
Consider the application.
Use the manufacturer’s application and option descriptions to guide your material review. Confirm the combination for the proposed product and assembly.
Applications described by TAKTL
- Field-set rainscreens
- Prefabricated facade assemblies
- Interior public-space walls
Published options
- Nine standard colors
- Nine standard textures
- Cast or Mediablast surface
- Project-specific color and texture
Prepare the UHPC panel schedule
Set out the facade
Share elevations with panel dimensions, quantities, joints and proposed returns. Identify field-set or prefabricated assembly zones. Ask TAKTL to confirm the current standard and custom format limits against this layout before fixing the panel schedule.
Approve a surface combination
Identify the color, texture and proposed Cast or Mediablast finish together. Request a sample of that combination, and record its reference with the drawing revision so the appearance brief and panel schedule describe the same selection.
Coordinate panel and attachment
State whether the design calls for visible fasteners or concealed undercut anchors. Provide the supporting wall information and request the corresponding TAKTL attachment details for review by the project engineer.
03 / Specification resources
Start with
the evidence.
Review the original manufacturer information, then request the documents for your exact construction and project conditions.
Manufacturer PDF / Linked source
TAKTL product data sheet
Original TAKTL file. Check its revision before specification.
Manufacturer product page
A|UHPC® Facade Elements at TAKTL
Current product descriptions and imagery from the manufacturer.
Project-specific / On request
Request a technical review package
Include the proposed panel, finish, attachment and project requirements.
Cladvera coordinates product inquiries, pricing and samples. Availability, lead time and final details are confirmed for each project. TAKTL performance and approvals apply only to the named manufacturer products and proposed assemblies.
Move this product into your project
Build a shortlist, then request the evidence, samples and commercial scope needed for your next decision.
Request product documents
Identify the proposed construction, reports, installation details and project requirements to review.
02 · Design approvalRequest a sample or mock-up
Define the finish, sample size and approval purpose. Scope, cost and timing are confirmed before ordering.
03 · ProcurementPrepare a product RFQ
Share quantities, drawings, delivery location and target dates for a project-specific quotation.
Each request includes A|UHPC® Facade Elements. Add other products in the request or bring your saved shortlist from the comparison page.
Continue your material review
Explore the applications listed for this product:
See the TAKTL Architectural UHPC collection for material context and manufacturer information.
Review material terminology and specification inputs in the ACM, HPL, UHPC and GFRP selection guide.
The following products share a listed application. Compare their construction, design intent and evidence before considering them for the same project.
A2 Fireproof Metal Composite Panel
Review for exterior facades: Metal-faced composite panel; confirm face metal, gauge and core for the offered construction.
Shandong Jinguang Group (Kinflare) · Custom GFRP
Custom GFRP architectural elements
Review for exterior facades: Molded glass-fiber reinforced polymer; resin, laminate and connection design are project-specific.
TAKTL · Architectural UHPC
KORSA™ Aggregate Panels
Review for exterior facades: TAKTL architectural ultra-high performance concrete; finish and geometry depend on the selected family.
Shared application tags do not establish equivalent performance or an approved substitution.
Coordinate the attachment system
Review TAKTL rails, clips, anchors and fasteners with the selected panel. The final attachment schedule requires project-specific engineering.
View TAKTL attachment components →